using System;
using Profinity.Scripting;
using Profinity.Comms.CANBus;
using Profinity.Model.DBC;
public class CSharpReadDBCSignalExample : ProfinityScript, IProfinityRunnableScript
{
public bool Run()
{
// Inject a CAN message with test data (matches Profinity test script pattern)
// Message: STW_ANGLHP_STAT (CAN ID 14)
// Signal: StW_AnglHP - raw value 0 gives -819.2 with factor 0.1 and offset -819.2
byte[] testData = new byte[8];
testData[0] = 0x00;
testData[1] = 0x00;
CanPacket testPacket = new(14, false, false, false, 8, CanPacket.Encoding.LittleEndian, testData);
Profinity.Console.WriteLine($"Created CAN packet with ID {testPacket.CanId}");
Profinity.CANBus.InjectReceivedCanPacket(testPacket);
Profinity.Console.WriteLine("CAN packet injected");
// Read the DBC signal via Profinity.DBC
// Requires a component named "TestDBCComponent" with message STW_ANGLHP_STAT and signal StW_AnglHP
// (or change these to match your profile)
string componentName = "TestDBCComponent";
string messageName = "STW_ANGLHP_STAT";
string signalName = "StW_AnglHP";
try
{
double signalValue = Profinity.DBC.GetDbcSignal(componentName, messageName, signalName).Value;
Profinity.Console.WriteLine($"Signal value from DBC: {signalValue}");
double expectedValue = (0 * 0.1) - 819.2;
if (Math.Abs(signalValue - expectedValue) < 0.01)
{
Profinity.Console.WriteLine($"Signal value matches expected: {expectedValue}");
}
else
{
Profinity.Console.WriteLine($"Signal value mismatch. Expected: {expectedValue}, Got: {signalValue}");
return false;
}
}
catch (Exception ex)
{
Profinity.Console.WriteLine($"Error reading DBC signal: {ex.Message}");
return false;
}
Profinity.Console.WriteLine("DBC read completed successfully");
return true;
}
}