Skip to content

Bug Report and Evaluation Feedback for CheXone #3

@amir333222111

Description

@amir333222111

Hello CheXone team,

First of all, thank you for developing and sharing CheXone. I really appreciate your work on building an open model for chest X-ray interpretation.

I tested the model using several random chest X-ray images from the internet, and overall it was interesting to evaluate. However, I noticed two issues that may need attention:

  1. The model frequently mentions comparisons such as “compared to prior views” or “no new changes compared to prior views,” even when only a single chest X-ray image was provided and there was no prior study available. This seems like a systematic reporting bug.

  2. In my informal testing, the diagnostic accuracy appears lower compared to CheXagent, especially for detailed radiology report generation.

Here is one example of the generated report:

“Assessing Lung Fields: The bilateral lung fields appear diffusely affected by small, discrete opacities distributed symmetrically without new changes compared to prior views...

Final Answer:
The cardiomediastinal silhouette is normal. There is persistent diffuse bilateral micronodular opacities seen. There is no pleural effusion or pneumothorax identified. The lungs are clear.”

As you can see, the report refers to prior views despite only a single first-time image being input. Also, there is some internal inconsistency (mentioning diffuse bilateral micronodular opacities while also concluding the lungs are clear).

I hope this feedback is helpful. Thank you again for making the model available.