Skip to content

Extended range for >3.3 V logic #2

@foucault

Description

@foucault

Logic is calculated by dividing the voltage set on AUX1 DAC by 2.62. In the basic range (±10 V) this limits the effective maximum logic voltage to 3.8 V. To get to 5 V logic AUX1 must be configured to operate at the extended range so that we can set the voltage to 13 V (effective 13.1/2.62 = 5 V). This requires support for extended range voltages in libarc2 and although provisions are already in place this has not been implemented at the higher level.