OCPP.Core Server API

Most messages are initiated by the chargers. But some messages are initiated by the OCPP backend. OCPP.Core currently supports:

  • Reset
  • UnlockConnector
  • SetChargingProfile (not verified)
  • ClearChargingProfile (not verified)

The OCPP.Core.Server offers an API for using these messages. Additionally the server supports a status request for the online status of all connected chargers. The management UI uses this API as well.

API format

The REST-API uses the following format:

/API/<command>[/chargepointId[/connectorId[/parameter]]]

For authentication/authorization purposes the API uses an API-key (like a password). This key must be send as an http header "X-API-Key" - see here. The allowed key is configured in the appsettings.json.

Functions

Status

Request the status of all connected chargers and connectors

/API/Status

The answer should be (example): [ { "id": "station42", "name": "myWallbox", "protocol": "ocpp1.6", "OnlineConnectors": { "1": { "Status": 1, "ChargeRateKW": null, "MeterKWH": null, "SoC": null } } } ]

Reset

Initiates a reset/reboot of the charger.

/API/Reset/station42

The answer should be: {"status"="Accepted"} or {"status"="Rejected"} or with OCPP 2.x {"status"="Scheduled"}

UnlockConnector

Send an unlock request for a certain connector

/API/UnlockConnector/station42/1

The answer should be: {"status"="Unlocked"} or {"status"="UnlockFailed"} or
OCPP1.6 {"status"="NotSupported"} OCPP2.x {"status"="OngoingAuthorizedTransaction"} or {"status"="UnknownConnector"}

SetChargingProfile

Sets a charging limit (power) for a certain connector. OCPP.Core does not support schedules. It sets the specified limit as a simple daily 24h schedule (=constant limit).

/API/SetChargingLimit/station42/1/2000W 

or

/API/SetChargingLimit/station42/1/16A

The answer should be: {"status"="Accepted"} or {"status"="Rejected"} or OCPP1.6 {"status"="NotSupported"}

Comment: Our Keba chargers are rejecting limits for specific connectors. But they accept connectorId=0 as the setting for all connectors.

ClearChargingProfile

Clears the charging limit (power) for a certain connector.

/API/ClearChargingLimit/station42/1"

The answer should be: {"status"="Accepted"} or {"status"="Unknown"}

RemoteStartTransaction

Request the charger to (remotely) start a transaction (simply explained: virtually presenting a specific charge tag to the charger)

/API/RemoteStartTransaction/station42/1/tag1234

The answer should be: {"status"="Accepted"} or {"status"="Rejected"}

RemoteStopTransaction

Request the charger to end a specific transaction.

/API/RemoteStopTransaction/station42/1

The answer should be: {"status"="Accepted"} or {"status"="Rejected"} The server checks the last transaction for the specified connector and return the http code 424 (FailedDependency) when no open transaction was found.

In general

These commands means that the server send a request to the charger and the charger needs to answer in a reasonable period of time. The server can not wait indefinitely and the OCPP server waits for 60 seconds. After that the API caller will geht the response {"status"="Timeout"}.