forked from MikaPetteriLundgren/Domoticz-Lua-scripts
-
Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathscript_time_doorsensorbatterytest.lua
More file actions
85 lines (74 loc) · 4.48 KB
/
script_time_doorsensorbatterytest.lua
File metadata and controls
85 lines (74 loc) · 4.48 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
--[[Scripts runs every hour and checks has Domoticz received data from the door sensor within current time
and pre-defined time period. In not, notification email is sent.
Time period is set to 604800s (1 week) by default.
Interval of sending email notifications is set 24h by default (86400s)
Own variable DoorSensorEmailSentSystemTime (type: Int) is used to store time in system seconds when last notification email was sent
Own variable DoorSensorTimePeriod (type: Int) is used to store temperature limit (min. value)
Own variable DoorSensorLastRunTime (type: Int) is used to store time when script ran last time (in system seconds)]]
--------------------------------
------ Variables to edit ------
--------------------------------
emailInterval = 86400 --Interval of sending email notifications
runInterval = 3600 --runInterval variable determines how often this script will run. Default 3600s (1h)
amountOfDoorSensors = 5 --This variable is used in for loops
frontDoor = "Etuovi" --Name of the device
backDoor = "Takaovi" --Name of the device
sideDoor = "Sivuovi" --Name of the device
garageDoor = "Autotallin ovi" --Name of the device
warehouseDoor = "Varaston ovi" --Name of the device
emailAddress = "ADD_EMAIL_ADDRESS_HERE" --Email address of recipient
subject = "Domoticz - Door switch may have a low battery level" --Subject of the email/SMS/notification
body = " switch may have a low battery level. Check battery!\n" --Body text of the email/SMS/notification. Name of the door(s) which battery level may be too low will be added at the beginning of body text by the script.
debug = false
--------------------------------
-- End of variables to edit --
--------------------------------
--Variables needed in the first place are initialized
lastRunTime = uservariables["DoorSensorLastRunTime"] --Time in system seconds when script ran last time
time = os.time() --System time in seconds is stored to time variable
commandArray = {}
--Function timeToSeconds converts time from format YYYY-MM-DD HH:MM:SS (Domoticz format) to seconds
function timeToSeconds (s)
year = string.sub(s, 1, 4)
month = string.sub(s, 6, 7)
day = string.sub(s, 9, 10)
hour = string.sub(s, 12, 13)
minutes = string.sub(s, 15, 16)
seconds = string.sub(s, 18, 19)
timeInSeconds = os.time{year=year, month=month, day=day, hour=hour, min=minutes, sec=seconds}
return timeInSeconds
end
if (time > lastRunTime + runInterval) then
print(" Door sensor battery test script running...")
--Rest of the variables are initialized
timeArray = {} --Last update times of door sensors are stored to this table
sortedTimeArray = {} --Sorted version of timeArray table(sorted from mix value to max value)
deviceArray = {frontDoor, backDoor, sideDoor, garageDoor, warehouseDoor} --Device variables are stored to this table
timePeriod = uservariables["DoorSensorTimePeriod"] --Pre-defined time period
lastEmailSent = uservariables["DoorSensorEmailSentSystemTime"] --Time in system seconds when last email was sent
--Received last update time per device is converted to seconds and stored to timeArray table
for i=1,amountOfDoorSensors,1 do
timeArray[i] = timeToSeconds(otherdevices_lastupdate[deviceArray[i]])
sortedTimeArray[i] = timeToSeconds(otherdevices_lastupdate[deviceArray[i]])
end
table.sort(sortedTimeArray) --Sort sortedTimeArray table from min value to max value
commandArray["Variable:DoorSensorLastRunTime"] = tostring(time) --Last run time of the script is updated to DoorSensorLastRunTime variable
if (debug) then
print("Following time stamps are coming in with otherdevices_lastupdate table (sorted from min value to max value): ")
for i=1,amountOfDoorSensors,1 do print(sortedTimeArray[i]) end
end
if ((time - sortedTimeArray[1] > timePeriod) and (time > lastEmailSent + emailInterval)) then
bodytext = ""
for i=1,amountOfDoorSensors,1 do
if (time - timeArray[i] > timePeriod) then
bodytext = bodytext..deviceArray[i]..body --Final body text is concatenated from name of the door(s) which battery level may be too low and content of body variable
end
end
print(bodytext)
commandArray["SendEmail"]=subject.."#"..bodytext.."#"..emailAddress
commandArray["Variable:DoorSensorEmailSentSystemTime"] = tostring(time) --Last time email was sent is updated to DoorSensorEmailSentSystemTime variable
elseif ((time - sortedTimeArray[1] > timePeriod) and (time <= lastEmailSent + emailInterval)) then
print("Door switch may have a low battery level, but it's too early to send new notification/email...")
end
end