ATTINYCellModule common wire problem cause measure error #115

@almol

Description

@almol

As described in https://community.openenergymonitor.org/t/diybms-v4/11292/3849 error on voltage measurements will be produced when contigous module is balancing because a common wire cabling between modules and cell batteries.
This causes the module to also begin to balance. Because it measures a higher voltage than the real one, and a chain effect occurs.

To fix it, it would be necessary that no voltage be measured if the adjoining module is balancing. This could be solved in several ways, for example taking advantage of the moment of data communication to stop balancing and perform the measurement.

We cannot assume that common wiring is not present in all battery configurations.