27 changes: 27 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -6,6 +6,8 @@ API changes can land even when the minor version is unchanged.

## [Unreleased]

## [1.3.0] - 2026-07-06

### Added
- `FieldMasterDevice` and `DebugFieldMasterDevice` (`powermeters/`): a driver
for the Coherent FieldMaster GS laser power/energy meter over RS-232 via an
Expand All @@ -18,6 +20,31 @@ API changes can land even when the minor version is unchanged.
other combinations until one replies, so a mismatched Menu self-heals. Note:
the meter only answers RS-232 while on its Home or Trend screen, and
`initializeDevice` raises with that hint when none of the terminators reply.
- `SerialPort.genericSerialConverterPorts()` and `isGenericSerialConverter()`,
plus the `genericSerialConverterVendors` table: discover connected ports that
come from a generic USB/RS-232 converter chip (FTDI, Prolific, Silicon Labs
CP210x, WCH CH34x), so an instrument with no USB identity of its own can be
located and disambiguated by the adaptor's serial number.
- `PhysicalDevice.usesGenericSerialConverter` flag (default `False`). A device
behind a generic converter matches any converter vendor (its `vidpids()`
expands to the whole table, product id wildcarded), and
`DeviceManager.candidateClassesForAutoDiscovery()` excludes such classes from
automatic probing, since their VID/PID identifies only the cable. FieldMaster,
oscilloscope, Echo and IntelliDrive are flagged and must be constructed
explicitly; Thorlabs (custom-EEPROM FTDI PID) stays a specific identity.

### Changed
- `PhysicalDevice.isCompatibleWith` treats a `None` product id in a `vidpids()`
pair as a wildcard that matches any product from that vendor. Concrete
`(vendor, product)` pairs are unaffected.

### Fixed
- `OISpectrometer.getSpectrum` no longer hangs. The wait for the "spectrum
ready" flag is now bounded (`maxRequests`/`maxWait`) and raises
`SpectrumRequestTimeoutError` instead of re-requesting a spectrum forever on a
transient USB glitch; transient `usb.core.USBError` (incl. `USBTimeoutError`)
during polling is absorbed and retried. `integrationTime` remains the first
optional argument, so all existing callers are unaffected.

## [1.1.0] - 2026-05-29

Expand Down
Loading