Expand Up @@ -558,7 +558,7 @@ report 99001501 "Subc. Create Transf. Order"
GetTransferToLocationCodeForPurchaseHeader(PurchaseHeader, VendorFromPurchOrder, TransferToLocationCode);

if TransferToLocationCode = '' then
exit(false);
VendorFromPurchOrder.TestField("Subc. Location Code");

PostedWIPQtyBase := GetWIPQtyBase(PurchaseLine, TransferToLocationCode);

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -1467,6 +1467,67 @@ codeunit 149911 "Subc. WIP Trans. Create Test"
'WIP Transfer Line description must not be cleared when Direct Transfer is enabled on the header.');
end;

[Test]
[HandlerFunctions('DoNotConfirmShowCreatedPurchOrderForSubcontracting')]
procedure WIPTransferCreationFailsWithTestFieldErrorWhenSubcLocationBlank()
var
Item: Record Item;
MachineCenter: array[2] of Record "Machine Center";
ProductionOrder: Record "Production Order";
PurchaseHeader: Record "Purchase Header";
PurchaseLine: Record "Purchase Line";
Vendor: Record Vendor;
WorkCenter: array[2] of Record "Work Center";
PurchaseHeaderPage: TestPage "Purchase Order";
begin
// [FEATURE] WIP Item Transfer for Subcontracting
// [SCENARIO 638815] When both the Vendor "Subc. Location Code" and the Purchase Header
// "Subc. Location Code" are blank, creating a WIP Transfer Order must raise a TestField
// error on Vendor "Subc. Location Code" instead of the generic "Nothing to create" error.

// [GIVEN] Complete subcontracting setup with Transfer WIP Item = true on the routing line
Initialize();

// [GIVEN] Work centers, machine centers, item with routing + BOM
SubcWarehouseLibrary.CreateAndCalculateNeededWorkAndMachineCenter(WorkCenter, MachineCenter, true);
SubcWarehouseLibrary.CreateItemForProductionIncludeRoutingAndProdBOM(Item, WorkCenter, MachineCenter);
SetTransferWIPItemOnRoutingLine(Item."Routing No.", WorkCenter[2]."No.", true);

// [GIVEN] Create and refresh released production order at the components location
LibraryManufacturing.CreateProductionOrder(
ProductionOrder, "Production Order Status"::Released,
ProductionOrder."Source Type"::Item, Item."No.", LibraryRandom.RandInt(10) + 5);
SetProdOrderLocationToCompSetupLocationAndRefresh(ProductionOrder);

// [GIVEN] Create Subcontracting Purchase Order from Prod. Order Routing
// (vendor already has a Subc. Location Code from CreateAndCalculateNeededWorkAndMachineCenter,
// so the purchase header inherits it; we will clear both afterwards)
SubcontractingMgmtLibrary.CreateSubcontractingOrderFromProdOrderRtngPage(Item."Routing No.", WorkCenter[2]."No.");

PurchaseLine.SetRange("Document Type", PurchaseLine."Document Type"::Order);
PurchaseLine.SetRange("Prod. Order No.", ProductionOrder."No.");
PurchaseLine.FindFirst();
PurchaseHeader.Get(PurchaseLine."Document Type", PurchaseLine."Document No.");

// [GIVEN] Both the Vendor "Subc. Location Code" and the Purchase Header "Subc. Location Code" are cleared
Vendor.Get(WorkCenter[2]."Subcontractor No.");
Vendor."Subc. Location Code" := '';
Vendor.Modify();

PurchaseHeader."Subc. Location Code" := '';
PurchaseHeader.Modify();

// [WHEN] Attempting to create a Transfer Order to the Subcontractor
PurchaseHeaderPage.OpenView();
PurchaseHeaderPage.GoToRecord(PurchaseHeader);
asserterror PurchaseHeaderPage.CreateTransfOrdToSubcontractor.Invoke();

// [THEN] A targeted TestField error on "Subc. Location Code" is raised
// (not the generic "Nothing to create" error — that is the current, unfixed behaviour)
Assert.ExpectedErrorCode('TestField');
Assert.ExpectedError('Subcontracting Location Code');
end;

[PageHandler]
procedure HandleTransferOrder(var TransfOrderPage: TestPage "Transfer Order")
begin
Expand Down
Loading